Product Details:
Power Supply | DC 4.75-5.25 V |
Current Consumption | 10-30 mA |
Plugging Cycles Jack | min.200 |
Fixing Screws | 4-40 UNC |
Max. Tightening Torque | 0.02 Nm |
Cable Diameter | 8 mm |
Contact Cover Screw | M3X15 |
Max Tightening Torque | 0.08 Nm |
Temperature Range | -20 Deg C- +75 Deg C |
Features:
Superior performance
High strength
Easy installation
Product Details:
Current Consumption | 10-30 mA |
Plugging Cycles Jack | min.200 |
Fixing Screws | 4-40 UNC |
Max Tightening Torque | 0.02 Nm |
Cable Diameter | 8 mm |
Temperature Range | -20 Deg C-+75 Deg C |
Packaging Type | Box |
The heavy metal Profibus connector Easy Conn PB is used for the connection of Profibus participants to the bus line. The fully visible diagnostic LEDs improve the installation considerably. Users can immediately check the status of bus activity, termination resistors, power supply and bus status at-a-glance.
Other Detail:
Product Details:
Brand | Siemens |
Part Number | 6GK1905-6AA00 |
Warranty | 6 Months |
Packaging Type | Box |
Weight | 0.143 lb |
Dimension | 2.165 x 6.142 x 1.378 Inch |
Product Details:
Material | Aluminum |
Dimension | 75,4 x 104 x 58,5mm |
Power | 9-28.8Vdc |
Consumption | 6VA |
Power Supply | 9 ~ 28,8 Vdc |
Fixation | DIN 35mm rail |
Degree of Protection | IP-20 |
Model Number | HDP-210 |
The Multi-channel Spur/Repeater Profibus DP HDP-210 enables the expansion and the consequent regeneration of the RS-485 communication signal, amplify data signals and couple Profibus DP network segments by branches.
Their main application are isolate noisy channels and segment the Profibus bus, while allowing better network structure layout.
The Profibus DP HUBHDP-210 should be used in the following situations:
In the Figure1a typical application of theHDP-210is illustrated.
Due to the characteristic impedance of RS-485 transceivers to be around 12K???,care must be taken to use a maximum of32 nodes per network segment, to notcompromising the communication channel. Therefore, to increase the scale of the network repeaters should be used.
In some circumstances, ground loops are present in the bus segments and must be canceled, thus as theHDP-210HUB has 5 isolated communication channels, its is possible to solve manyproblems of the physical layer.
When the cable length limit by the communication speed is reached, theHDP-210HUB assists in the configuration of fastand big networks, with amplifying and regenerating the data signal.
Product Details:
Model Name/Number | TDP-100 |
Brand | DLG |
Material | ABS plastic |
Power | 24Vdc |
DIN Rail | 35 mm |
Baud Rates | 9.6K,19.2K,45.45K,93.75K,187.5K,500K,1.5M,3M,6M and 12M |
Fixation | DIN35 rail (DIN EN 60715 TH35) |
Dimension | 94 x 27 x 77.5 mm |
Profibus TDP-100 Terminator is an active terminator created to make possible handling any communication bus node in full operation. Thus the nodes can be turned off, removed or replaced without harming the transfer of data from the other nodes. The devices on both ends of the net can be removed without affecting the intermediary nodes, whose termination ends must stay constantly turned on.
The Profibus DP Terminator can be mounted on standard 35mm DIN rail. An indication LED indicates the status of the 24V source and the correct bus operation.
The Power supply and the communication cables are connected by terminals with fixed screws and also the Profibus bus can be accessed by a DB9 connector.
The Profibus DP RepeaterHDP-200 should be used in the following situations:
In the Figure1,a typical application of theHDP-200is illustrated.
Due to the characteristic impedance of RS-485 transceivers to be around 12K,care must be taken to use a maximum of32 nodes per network segment, to notcompromising the communication channel.
Therefore, to increase the scale of the network repeaters should be used.In some circumstances, ground loops are present in the bus segments and must be canceled, thus as the HDP-200repeater has 2 isolated communication channels, it is possible to solve many problems of the physical layer.
When the cable length limit by the communication speed is reached, the HDP-200 repeater assists in the configuration of fastand big networks, with amplifying and regenerating the data signal.
Product Details:
Power | 24 V DC +- 6 V |
Part Number | 1712.180 |
Connector | 2 X RJ45,D-Sub,female,9-pin |
Dimension | 100 x 52 x 70 mm (without connector) |
Weight | 150 g |
Product Details:
Network Type | 4G |
Operating Temperature | 0 to 60 DegreeC / 32 to 140 DegreeF |
Humidity | 10 to 95% |
Dimension | 101 x 22.5 x 120 mm / 3.98 x 0.886 x 4.72 in |
Weight | 0.15 kg / 0.33lb |
Isolation | 500 V galvanic |
Speed | 9.6 kBit/s - 12 MBit/s |
Protocols | Profibus DP-V0 and DP-V1 Slave |
Speed | 250 kBit/s |
Storage temperature | -25 to 85 Deg C / -13 to 185 Deg F |
Esepro is a Profibus gateway specifically designed to interface Woodward's Easygen series genset controls with Profibus-DP networks. It interfaces via the Can bus with the Woodward controls and is easy to configure using standard Profibus configuration tools like Simatic Manager.
A single Esepro added to the Can network will make all Visualisation Data of connected Woodward Can open controls available without adding additional load to the Can bus communication. The Visualisation Data is buffered in the Esepro gateway which decouples Profibus’ cyclic process I/O from the Can open cyclic TXPDO transfers.
A single Esepro added to the Can network will make all Visualisation Data of connected Woodward Can open controls available without adding additional load to the Can bus communication. In addition concurrent and fast read and write access to device Parameter IDs is possible utilising parallel Can open SDO transfers.
The Esepro appears as a modular I/O module in the Profibus configuration tool.
The Esepro offers three different methods to map data into the PLC's process I/O image to suit different application requirements and programming styles. Visualisation Data of connected Easygen and LS-5 devices can be mapped directly into the PLC's process image. For larger data tables which exceeds the Profibus I/O space, a profile-style indexed mapping similar to the Profidrive standard can be used. Alternatively access to larger data tables via acyclic DP-V1 transfers is also possible. In addition, read and write access to the Easygen’s device Parameter IDs is possible utilising acyclic DP-V1 transfers which are internally translated to CANopen SDO transfers.
Common Applications Include:
Product Details:
Operating Temperature | 0 Deg C to 60 Degree C / 32 to 140 Degree F |
Humidity | 10 to 95% |
Weight | 0.15 kg / 0.33lb |
Speed | 250 kBit/s |
Max. number of connected nodes | 64 |
Storage Temperature | 25 Deg to 80 Deg C / -13 to 185 Deg F |
Dimensions | 101 x 22.5 x 120 mm / 3.98 x 0.886 x 4.72 Inch |
Mounting | 35 mm DIN rail (EN 60715) |
Esenet is an Ethernet gateway specifically designed to interface Woodward's Easygen series genset controls with Modbus/TCP networks. It interfaces via the load sharing CAN bus with the Woodward controls.
The Esenet offers cost savings compared to traditional Modbus/TCP to RTU gateways as no separate RS-485 wiring is required. In addition the Esenet takes advantage of the multi-master capability and fast transmission speed of CAN to offer short Modbus/TCP poll cycles as well as concurrent access. Both cannot be achieved using conventional serial Modbus half-duplex data transfers.
A single Esenet added to the CAN network will make all Visualisation Data of connected Woodward Can open controls available without adding additional load to the Can bus communication. In addition concurrent and fast read and write access to device Parameter IDs is possible utilising parallel Can open SDO transfers.
Usage and configuration of the gateway is simple and conveniently performed using a web browser which connects to the embedded web server.
Common Applications Include:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Model Name/Number | ODOT-S7MPIV2.0 |
Number Of Ports/Pins | 2 |
Power | Max.l00mA@24V |
Temperature | 0 -60 |
Part Number | ODOT-S7MPIV2.0 |
Dimension | 65*30*17mm |
Input Power | 24 VDC+-20% |
Additional Information:
Product Details:
Model Number | 7009727BB12 |
Dimensions | 64 x 40 x 17 mm |
Weight | Approx. 40 g |
Transmission Rate | Max 12 Mbps |
Max Outside Diameter | 8.0 mm |
Connection type | 4 Terminals |
Current Consumption | Max . 12.5 mA |
Ambient Temperature | 0 Deg C - +60 Deg C |
Storage temperature | -25 Deg C - +80 Deg C |
Relative Humidity | 75 % at +25 DegreeC |
Product Details:
Brand | BluBoxx |
Length | 100 m |
Diameter | 0.5 mm |
Material | PVC |
Power/Voltage | 110 VDC |
Temperature Range | 120 Degree C |